동상모형실험을 통한 아스팔트 포장체의 동결 및 처짐 특성

신은철, 황순갑, 박정준 · Journal of the Korean Geosynthetic Society · 2012

In this paper, the frost heaving and thawing characteristics of flexible pavement structure were evaluated in the large scale freezer which have a specification of temperature range -20℃∼10℃ and 3.2 m(L)×3.2 m(B)×2.4 m(H) in size. The insulated steel box with the size of 0.9 m(L)×0.9 m(B)×0.9 m(H) was used to simulate actual pavement road structure. The variation of temperature, frost heave amount and frost heave pressure were measured through the instrument of TDS-602 data logger. LFWD (light falling weight deflectometer) was used to determine the change of deflection due to the frost heaving and thawing. Furthermore, the influence of aggregate layer to the freezing of the subgrade soil was studied to verify the function and effectiveness of the anti-freezing layer.

Cited by 0 works.