볼밸브를 사용한 송수펌프장에서의 수격현상
김경엽, 김점배 · 대한기계학회 춘추학술대회 · 2004
The waterhammer has recently become more important because thc pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex, When the pumps arc started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity, In this paper, the Held tests on the weterhemmer by the startup. stoppage. and power failure of a centrifugal pump were carried out for Yougma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.
Cited by 2 works.