내연발전기 여자시스템 제어기 절체 불가 원인 분석

신만수, 이주현, 정태원 · 대한전기학회 학술대회 논문집 · 2010

The excitation system for diesel generator consists of double redundancy module and has been operating since 2008. Recently, the system was tripped by reason of failure of changeover of ther controller. By the way, it is very difficult to checkout the trip cause, because the checkout tool of software program was not existed. The journey is described to checkout the reason of failure of changeover.

Cited by 0 works.