중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰
김민호, 천인범, 이대훈 · 한국자동차공학회논문집 · 2002
The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system in a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFO simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity field, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-seclional area and radius of bifurcated region. In addition, a one-dimensional program based on Bemoulli equation was developed to obtain optimum diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFO Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.
Cited by 0 works.