동시 다성분 분석법에 의한 농산물 중 펜시쿠론 분석

박영혜, 한창호, 김애경 et al. · 2013

An analytical method for the simultaneous determination of pencycuron in agricultural products was established by using GC-NPD. The method was validated through the guidelines of linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision. The calibration curve of pencycuron was linear over the concentration range of 0.02-2 mg/kg with correlation coefficient of above 0.9999. The limits of detection and quantification were 0.005 and 0.02 mg/kg. Mean recoveries of pencycuron for each sample were 79.6-107.5% at the level of 0.02 mg/kg and 86.4-112.1% at the level of 0.2 mg/kg and 84.0-104.9% at the level of 1 mg/kg. Relative standard deviation (RSD) in recoveries were all less than 5%. The intra- and inter-day precision (RSD) were 1.6-3.0% and 5.3-11.5%, respectively. The result of validation indicated that this method was accurate and sensitive assay.

Cited by 0 works.