임펠러 엇갈림 각의 변화에 따른 펌프 성능 특성 고찰
윤현기, 박무룡, 유일수 et al. · 대한기계학회 춘추학술대회 · 2009
The operating cost is highly affected by a small difference of pump efficiency around 1~2% in a high capacity pump. So, the detailed revision of the design is required. In the present study, the pump performance has been investigated experimentally and numerically with a change of a stagger angle. The axis of rotation of the stagger angle is placed at the center of the sectional area of the blade between the hub and shroud. The stagger angle is set as -2, -1, 1 and 2 degree from the original design. Performance analysis of each stagger angle is achieved with various flow rates. Cavitation characteristic is also studied at this time. The impeller and diffuser have been investigated numerically by using the commercial code CFX, k-w based SST turbulent model, homogeneous flow model and Rayleigh Plesset cavitation model. It shows good performance that the stagger angle is one degree. Its performance is very similar with the original design near the design point, but better than 2~3% at the high flow rate. The result of the cavitation characteristicshows that the net positive section head (NPSH) is lower than 10% compared with the original design.
Cited by 0 works.