초고층 주거건물 커튼월의 창호부 결로 성능평가에 관한 연구
석호태, 정만석, 곽현철 et al. · 대한건축학회 논문집 - 계획계 · 2005
The purpose of this study is thermal performance simulation about various type that can apply in the high-rise residential building to estimate heat transmission performance of window that is consisted of frame and glazing in curtain wall. The result of this study are summarized as follows. First, temperature deflection of frame according to change of frame differed by 2.8℃~23.2℃ and the interior & exterior temperature according to glass type differed by 13.7℃. Second, aluminum frame is much the heat flow amount through frame and PVC frame is much the heat flow amount through joint region of frame-glazing. Third, the case that apply krypton is high by 0.73~1.06℃ than the case that apply air in gas. Double seal that used butyl is high by 0.6~0.85℃ than aluminum in spacer. Fourth, when compared result of window frame by type of thermal break, the heat flow amount of Azon is a few by 35.5~50.6 W/m2 than polyamid and polythermid in the heat flow amount and heat flow amount deflection, it reduced by 1.1~1.2% heat flow amount. Fifth, when analyzed improved proposal of window and existing plan through simulation, improved proposal is superior from general side of the interior and exterior temperature, thermal break surrounding temperature and temperature deflection, the heat flow amount, temperature of frame end, etc. Therefore, if it was used improved proposal with effect that improve the heat flow amount of 29.7% in curtain wall of high-rise residential building, it may improve window heat transmission performance of curtain wall.
Cited by 0 works.