오토클레이브 양생에 따른 콘크리트 마감재의 표면특성에 관한 연구

최선미, 정지용, 정은혜 et al. · 한국건축시공학회 학술.기술논문발표회 논문집 · 2005

The surface of concrete tiles is weak in moisture that it occurrenced efflorescence, but in the former study we found that it is possible to ensure moisture stability of concrete surface by autoclaving. So this study is to discuss the moisture stability and physical properties of high-strength glossy concrete according to time and temperature of autoclave curing. As the results, by increasing time and temperature of autoclave curing, compressive strength and surface hardness increased and glossiness decreased. In the case to 3 hour and 180℃ of autoclave curing, there is not effloescences in mosture stability test.

Cited by 0 works.