평행관류 열교환기에서의 최적 냉매분배구조
나병철, 진대현, 윤점열 · 1997
The energy efficiency ratio (EER) of the air-conditioner depends on the heat exchanger capacity as well as compressor efficiency. This study is to optimize the refrigerant flow pass in the parallel flow type condenser used as condenser for air-conditioner to increase the heat transfer performance without changing the heat exchanger size and air flow rate. Condensation heat transfer coefficient decreases as the mass flux and the vapor quality decrease. The condensation heat transfer coefficient decrease with the decrease of vapor quality could be compensated by the mass flux increase that is possible in the parallel flow type heat exchanger with manipulating the flow passing area. According to this approach, the EER could be increased by 0.04 ㎉/W.hr in the 2HP air-conditioner.