실린더 블럭 진동 신호를 이용한 스파크 점화 기관의 단순 노킹 제어

함윤영, 이재형, 장광수 et al. · 한국자동차공학회 춘 추계 학술대회 논문집 · 1994

To minimize fuel efficiency loss and power loss by knocking, spark timing was controlled near the knock occuring limit, using cylinder block vibration signal. Vibration signals of a 1498cc four-cylinder spark ignition engine was measured using accelerometer which was attached to the cylinder block. The signals from this sensor was put through the band-pass filter and knock occurrence was determined by comparator. In this study, the simple knock control algorithm in which spark timing was advanced when knock occurred and retarded when knock did not occur was tested experimentally. Experiment was carried out varying the correction interval of spark timing advance at WOT. 2000 rpm. Knock occurrence was reduced when the correction interval increased and when retard crank angle was 3° rather than 2° . The engine torque was increased with this knock control system, without continuous knocking.

Cited by 2 works.