가정용 냉장고의 응축기 적용을 위한 판형 핀-관 열교환기의 성능실험

손영우, 이장호, 김무환 et al. · 대한기계학회 춘추학술대회 · 2008

Experimental performance of plate fin-tube heat exchanger is studied to check the possibility of applying to the condenser of household refrigerator. It has lighter weight and lower price of 30% than the conventional circular-fin condenser which has been used. In this experimental study, the refrigerant supplying system instead of the hot water supplying system was used to test condenser in the similar condition with real bousehold refrigerator. It has following test conditions: inlet air temperature of 3 2℃, inlet air velocity of 0.63 ㎧, inlet refrigerant temperature of 60℃, and saturation temperature of 44.5℃. Totally, four kinds of heat exchanger are tested, and heat transfer rate, pressure drop, are evaluated for each test sample.

Cited by 0 works.