전동/발전기 코어에 의한 초전도 플라이휠 에너지 저장장치의 회전손실 특성 평가

李丁必, 韓塋熙, 丁世庸 et al. · 2007

In this paper, the rotational loss of the superconductor flywheel energy storage system (SFES) by motor/generator stator core was assessed. To do this, the vertical axial type SFES with journal type superconductor bearing was manufactured. To quantitatively assess the rotational loss by the stator core, the rotational losses by superconductor bearing and the degree of a vacuum were measured. In case of variation of the inner radius and outer radius of the stator core, the rotational losses were measured. From the experimental results, It is confirmed that the rotational loss can be reduced by means of the optimal stator core design.

Cited by 0 works.

Authors