电站锅炉选择性非催化还原脱硝实验研究——还原区温度、尿素溶液喷射体积流量的影响

吕洪坤, 杨卫娟, 周俊虎 et al. · 2009

Selective non-catalytic reduction (SNCR) using urea solution injection was applied to a HG-410/9.8-YW15 boiler on the base of conventional pulverized-coal reburning process. Experiments were mainly conducted under 280, 345 and 410 t/b. Results showed that NO(subscript x) emission was below 200 mg/m^3 (standard condition, 6% O2 volume fraction, dry gas) when SNCR was operating, namely a NO(subscript x) reduction of 40%-60%. It was favorable to injecting urea solution using the injection layer where the hearth temperature was about 900℃, higher or lower might be disadvantageous to NO(subscript x) reduction, and the lower temperature also resulted in more ammonia slip. The increase of layer's injection volume flow rate could improve NO(subscript x) reduction efficiency, the economical injection volume flow rate in the experimental range was 1.0-1.6 m^3•h^(-1) and the larger injection volume flow rate also led to lower emission of NH3 and N2O. But the water injected into the hearth resulted in a decrease of boiler efficiency by almost 0.5%.

Cited by 0 works.

Authors