엔진실 차폐장치의 열전달특성에 관한 수치적 연구

배이석, 유근종, 최훈기 · 대한기계학회 춘추학술대회 · 2008

In engine room, a good enclosure system is necessary for reducing noise but installing enclosure system in engine room cause a bad influence upon the cooling performance because of poor ventilation. The cooling efficiency of enclosure system can be improved by changing speed of fan and flow path for ventilation of engine room. In this study, numerical analysis is performed to assess cooling effect of enclosure system using finite volume method. The RNG k-e model is adopted for turbulence model along with heat exchanger model and porous media model for heat exchanger analysis and moving reference frame model for rotational fan. Cold flow analysis result proves reasonable agreement with experimental data. Analysis results show direct effect of velocity and temperature distribution on cooling ability of enclosure system. Compare with the engine room which has no enclosure system, the case with total enclosure system which has box hole flow path and 1570rpm of fan speed shows the proper cooling capacity.

Cited by 0 works.