천장패널 이용 복사냉방시스템의 냉방특성에 관한 실험적 연구
김용기, 우남섭, 한태수 et al. · 대한설비공학회 동계학술발표회 논문집 · 2009
One of the hybrid(load-sharing) HVAC systems that attracted attention for its potential for energy savings while providing high thermal comfort is a radiant cooling system using ceiling panels. Panel systems may be combined either with a central forced-air system or with decentralized convective systems, or with in-space fan-coil units. In this study, the ceiling radiant panel system is combined with a fan-coil unit for the cooling load sharing and the dehumidification. The main thrust of this research is to analysis the cooling characteristic of the hybrid HVAC system with ceiling panels and to estimate the cooling load fraction of between fan-coil units and ceiling radiant panel under various condition. It was found that the cooling load fraction of chilled ceiling panels can be enhanced in the air volume of a fan-coil unit by 40~67% under the dew point control.
Cited by 0 works.