소음 상사를 이용한 직교류 홴의 유동 소음에 관한 수치해석 연구

이명성, 강성원, 허남건 et al. · 대한기계학회 춘추학술대회 · 2011

The flow noise of a cross-flow fan in an air conditioner indoor unit is investigated by a 2-D CFD simulation and acoustic analogy analysis. Transient flow field is obtained by solving the unsteady Reynolds-Averaged Navier-Stokes equation with the arbitrary sliding interface method to slide the grid for the relative motion of the rotating cross-flow fan. To predict the flow noise generated due to the cross-flow fan, an acoustic analogy analysis is performed with Ffowcs-Williams Hawkings model. The results show the details of transient flow field inside the air-conditioner including the typical eccentric vortex, which is appeared in the vicinity of the stabilizer. The strong interaction between the eccentric vortex and stabilizer is also well predicted, which is well known as the primary factor of the flow noise of the cross-flow fan. In order to validate the present analysis, the numerical result is compared with available experimental data such as the overall sound pressure level.

Cited by 0 works.