건물 영구배수와 생활배수 온도차에너지 이용에 관한 연구

이성락, 배민호, 권병효 et al. · 대한설비공학회 하계학술발표회 논문집 · 2010

A study was carried out to utilize the temperature difference energy produced by both permanent ground water and building waste water. For this purpose, the double heat source system, which is composed of permanent ground water and building waste water, was designed for covering a part of heating and cooling load in a building. The field test was carried out during a heating season. The heat of 170,000 kcal a day was produced and used to heat the building. The heat gain obtained from both the permanent ground water and the waste water was analyzed to be four times higher than the one from the single geothermal heat pump system. The economic evaluation considering the initial investment and the energy cost showed that the double heat source system is more economical than the single geothermal heat pump system and the absorption chiller-heater system.

Cited by 0 works.