플라즈마 화학 증착된 질화 규소 미소 구조물의 탄성 계수 측정
Jae Hyun Kim, 이학주, 한승우 et al. · 대한기계학회 춘추학술대회 · 2005
Silicon nitride micro-structures are extensively utilized in MEMS applications. In order to design and simulate a silicon nitride structure in MEMS, its mechanical property is required to be measured. In this study, the silicon nitride thin film of about 1000 ㎚ thick is deposited on silicon substrate by Plasma Enhanced Chemical Vapor Deposition (PECVD) method and patterned by optical lithography. The silicon nitride microstructures are released by silicon bulk etching process (DRIE). The mechanical behaviors of the microstructures are measured by strip bending test and the elastic modulus is extracted from the measured stressstrain curve. The measured elastic modulus is compared with that measured by nanoindentation.