포스트텐션 전이슬래브의 구조설계 및 긴장재 배치방법
윤장근, 강수민, 김욱종 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2010
The transfer system that transit the high concentrated loads from upper level walls or columns to lower level transfer columns is very common way in apartment building, office and hotel design and construction. In this system, transfer slab design is very important because it should carry and resist high gravity load and lateral load from superstructure. If transfer slab is designed by reinforced concrete, it is usually required that considerably high depth and large reinforcement quantities. So, it is necessary to reduce the depth and reinforcements of transfer slab. Post-tensioning is an effective way to reduce the depth and reinforcement of transfer slab. In this research, some alternative PT analyses are conducted by CEDRUS software.
Cited by 0 works.