순환식 멀티존 공조방식이 적용된 병동의 부유균 확산 및 제거
성민기 · 대한건축학회 학술발표대회 논문집 - 계획계 · 2011
This study shows the prevention of the microbial contamination using air filters and in-duct ultraviolet germicidal irradiation (ID-UVGI) in a hospital where multi-zone air handling units (AHUs) were being operated for multiple ward areas. The results of monitoring the microbial contamination showed that the airborne microbes were assumed to be eliminated by both air filters and the UVGI system at the same time. The UVGI system was more effective for removing the surface microbes rather than airborne bacteria passing through air filters according to the result of surface microbes monitoring. Appropriate combination of air filters and UVGI system is assumed to be effective for preventing microbial contamination in hospital buildings.
Cited by 0 works.