Активная виброизоляцияфундаментов турбоагрегатов

Лавелин Виталий Евгеньевич, Ямов Владимир Иванович · Академический вестник УралНИИпроект РААСН · 2015

Survey of existing turbogenerator foundation structures carried out, characteristic of low-tuned and high-tuned foundations is described. The method of active vibroisolation by means of steel spring elements is considered as a way to overcome high vibration.