배수공 내 스케일 생성 방지 기술의 현장 적용성 평가

주익찬, 이종휘, 김현기 et al. · 2012

The calcium hydroxide(Ca(OH)₂) which is the cement hydrate flowed into the tunnel by groundwater is reacted with microorganism in the soil, carbon dioxide(CO₂) and the vehicle’s exhaust gas(SO₃). So its by-products are precipitated at the drainage pipe and these cause the drainage clogging. By this phenomenon, Degradation of water flow at the drainage system of the tunnel occurred and also pore water pressure is increased. Hence the acceleration of seepage and degradation of lining is occurred. The purpose of this study is to evaluate the field applicability of the Quantum Stick and Magnetic treatment in prevention of scale deposits at the Namsan OO tunnel and the Zone OOO of subway. These technologies were installed into drainpipes with their performance monitored through occasional site visits. SEM and XRD were also performed on scale collected from these drainpipes. As a result, in case which factor technology is applied, scale creation is remarkably decreased and especially Quantum Stick treatment performing better than Magnetic treatment. Therefore, additional application of Quantum Stick or Magnetic treatment to the existing drainage is expected to decrease the drainage clogging of the drainage.

Cited by 0 works.

Authors

References