강판 전단벽을 사용한 모듈러 시스템의 내진 성능 평가
Tae Hyong Kim, 이두용, 하태휴 et al. · 대한건축학회 학술발표대회 논문집 · 2012
This study suggests the system that is able to resist seismic efficiently by using steel stud and plate, and evaluates its seismic performance. In order to simplify the process of manufacturing module, a panel that will be installed on the wall in module was made up of four units. In this system, instead of using weld, screw bolt was used to improve the step of fabrication. The paper presents that initial strength of the load-bearing wall modular system with steel plates was highly increased, compared to non-load bearing modular system. In addition, lateral resistance capacity and energy dissipation were improved as well. Lastly, it was discovered that the steel plate with slit-damper showed better energy dissipation than a steel plate.
Cited by 0 works.