유하액막이 크레비스형 베이퍼챔버 히트파이프의 냉각성능에 미치는 영향

배재영, 김준하, 황언화 et al. · 대한설비공학회 동계학술발표회 논문집 · 2014

About 85% of electrical energy used in LED was converted into heat energy. This thermoemission causes a failure in electrical equipment, performance deterioration and shorten the life of the LED. In order to solve this problem, heat pipe was used in many previous study. The study was conducted using Crevice Type Vapor Chamber Heat Pipe for the heat transfer in the vertically installed position. The purpose of this study is to know influence of the falling liquid film on the cooling performance of Crevice Type Vapor Chamber Heat Pipe and operating principle of Crevice Type Vapor Chamber Heat Pipe. Working fluid was R-141b and its charging ratio was 60%vol. of vapor chamber volume. From the experiment result, when inserting the tube to the heating surface, the temperature of LED chip and PCB was relatively low as 95.4℃, 75.8℃ respectively.