현장 측정 자료를 이용한 중량바닥충격음의 평가방법 검토
신훈, 백건종, 송민정 et al. · 대한건축학회 학술발표대회 논문집 - 계획계 · 2008
After floor impact sound insulation performance criteria establishment. the majority domestic apartment houses' slab are constructed by 108mm or 210㎜ thickness. In this study, the necessity of review on existing floor impact sound insulation performance method is proposed based on the field test data to check existing rating method is adequate for domestic apartment houses. The results of this study are followings ; 1) The 210mm thickness slab has more deep level decrease characteristics above 120㎐ band than that of 180mm thickness slab's 2) 27.5% of 180㎜ thickness slabs are suitable for floor impact sound insulation performance criteria, whereas 65% of 210㎜ slabs do. 3) In comparison of main contribution frequency band for determination of single rating index, 63㎐ is very contributive in 210㎜ slabs. this result need more study to find out the cause. In comparison of single rating index between bang machine test and ball test. there is a big difference between the two and this phenomenon is frequent in 210㎜ slab results.
Cited by 0 works.