확대부 내열재의 접착계면 결함 검출을 위한 초음파 공진 신호 분석
김동륜, Jae‐Hoon Kim, 임수용 et al. · 한국추진공학회 학술대회논문집 · 2012
The ultrasonic resonance method was applied to detect the disbond interface and empty layer between steel and FRP of the exit cone. The ultrasonic resonance method can easily detect the disbond interface and empty layer by amplifying the ultrasonic signal, but pulse echo method is difficult to distinguish adhesive interface from disbond interface or empty layer. The resonance frequency was predicted using the pressure reflection coefficient of 3-layered medium, and measured from ultrasonic signal of the test block using Fast Fourier Transform. The ultrasonic resonance proved that the predicted resonance frequency was in good agreement with the measured resonance frequency.
Cited by 0 works.