한국형 신형원전의 피동보조급수계통 설계
김한곤, 천종, 김문수 · 대한기계학회 춘추학술대회 · 2010
The passive safety facility is being developed in the Advanced Power Reactor Plus(APR+) by Korea Hydro & Nuclear Power Co. APR+ is a GEN Ⅲ+ reactor on the basis of the APR1400. The Passive Auxiliary Feedwater System(PAFS) is one of the passive safety features adopted in APR+. The PAFS of the APR+ replaces the conventional active auxiliary feedwater system of the APR 1400 by introducing a natural driving force mechanism while maintaining the system's basic function of cooling down the primary side and removing the decay heat. To satisfy the single failure criterion, the PAFS is composed of two independent trains. Each train has one steam condensing heat exchanger of 100% capability and one. PCCT (Passive Condensation Cooling water Tank) of 100% capability. Basic design is underway and separate effect tests and integral effect tests will be performed to demonstrate the performance of the PAFS.
Cited by 0 works.