격납건물 관통 고립배관부의 열적과압화 건전성

신혜영, 정선미, 박영섭 · 대한기계학회 춘추학술대회 · 2010

One of the technical issues addressed in Generic Letter 96-06 by the U.S. NRC is related to the possibility of thermally induced over-pressurization (TIP) of isolated penetration piping through the containment vessel during design basis accidents such as a loss-of-coolant accident (LOCA) or a main steam line break (MSLB). This is a safety-significant issue, because TIP can threaten the integrity of isolated sections of penetration piping, and this in turn can cause a failure of intended isolation function of the containment vessel during the conditions of a LOCA or MSLB. A procedure and a method to evaluate the structural integrity of the isolated piping are established for domestic application by studying the status and trends abroad to deal with this issue. Resolution results in the USA are surveyed and statistically analysed, research outputs are reviewed in order to be utilized in the steps of the evaluation, and the results is described in this paper.