자동차용 대체냉매 직접팽창 시스템 성능 평가를 위한 실험적 연구

이호성, 원종필, 조중원 et al. · 한국자동차공학회 부문종합 학술대회 · 2012

The aim of this study is to investigate the performance of air conditioning system for alternative refrigerants with the direct expansion system. Due to environmental regulation as a global issue, R-134a, present mobile A/C refrigerant, need to be substituted before long. Among possible alternative refrigerants, R-1234yf has been highly regarded in Mobile Air Conditioning System(MACS) because of similar operating pressure characteristic and technologies to apply have been studied. In this study, R-1234yf and R-744, which have direct expansion system like the present refrigerant, were analyzed on the performance, such as cooling capacity and coefficient of performance(COP), compared to R-134a. As the results of various experiments which were fulfilled like real operating conditions on the road, averaged cooling capacity of R-1234yf was about 96.0 % while that of R-744 was about 97.0 % compared to R-134a and in case of averaged COP, R-1234yf was about 92.0 % while R-744 was about 70 % . From this, R-1234yf and R-744 need additional technical developments to cope with insufficient performance, such as internal heat exchanger re-design and expansion valves set-up value. Further studies of improved alternative refrigerant A/C system with the direct expansion will be required to change a refrigerant for MACS.