DOC 장착시 전기히터/촉매 복합 재생방식 매연여과장치의 성능향상에 관한 연구
최현하, 김홍석, 정용일 et al. · 한국자동차공학회 춘 추계 학술대회 논문집 · 2006
H-CDPF system regenerates the ceramic monolith filter both actively by an electrical heater and passively by a CDPF. The aim of this study is to compare the performance of the DOC coupled H-CDPF system with the DOC uncoupled H-CDPF system. In this study, the H-CDPF system was installed on the midium duty diesel engine of which already meets EURO-2 standards. The BPT of the DOC coupled H-CDPF system was about 40℃ lower than that of DOC uncoupled H-CDPF system. The DOC coupled H-CDPF system enhanced the active regeneration by the electrical heater at an idle engine condition. Also in the durability test which simulated actual city driving conditions, the DOC coupled H-CDPF system showed better regeneration characteristics.