열선유속계와 동적배기유동모사장치를 이용한 배기계 유동 및 유동균일도 해석에 관한 연구

전대일, 이강영, 황인구 et al. · 대한기계학회 춘추학술대회 · 2008

The CCC (Closed-coupled Catalyst Converter) is important for emission regulations that become stringent, and its distribution has an effect on that. The CCC manifold has complex flow caused by the pulsating flows that are emitted by the exhaust ports. It makes the flow distribution is not uniform. To improve the ability and durability of catalyst, the flow distribution has to be uniform. So measurement of flow distribution is needed. It can be done with computational fluid dynamics. However, such simulations must be verified with experimental data. In this study, conventional manifold of a 4-cylinder engine (with 900 cell CCC system) was performed to investigate the flow characteristic and distribution of exhaust gas. The flow velocity was measured using simulated dynamic flow bench and hot-wire anemometer. The effect of different exhaust ports opening and closing was determined by comparing the flow characteristics.

Cited by 0 works.

Authors