에너지성능분석 및 감성평가에 의한 오피스 창호의 적정 투과율 선정
김병수, 김정신, 임오연 · 2004
The purpose of this study is to select the optimal transmittance rate of windows in office buildings through subjective evaluation and energy performance analysis (computer simulation program; DOE 2.1E). The results are as follows; 1) In the subjective evaluation experiment, minimum transmittance of the glass is GE 30% and LT 70%, but the optimal transmittance rate is concluded in 40%~60%. 2) As a result of the energy performance analysis, it is desirable for the building of consumptive with mainly air-conditioning to make transmittance as 40-60%. 3) Comparing foreign study on minimum and optimal transmittance rate is 25%∼ 38%, the minimum transmittance of this study is almost the same. But for the optimal transmittance rate, 20% more is needed for KOREAN.
Cited by 0 works.