현장 실측을 통한 조명시스템 사용행태에 관한 연구
김효인, 윤근영 · 한국건축친환경설비학회 학술발표대회 논문집 · 2011
Lighting load for the rise of indoor illuminance level has been increased recently, and occupant behaviour occurs a large energy deviation. This study aims to investigate the lighting conditions, lighting use patterns, and their relationship. The field measurement was implemented in three offices from June 1 to August 31. External and indoor illuminances, and the use of lighting were monitored at 10 minute intervals. The results of the field measurement reveal the illuminance on workplane and lighting use patterns by occupants. This study demonstrate that occupants use artificial lighting more than 93% during occupied period, and the lighting use pattern in the monitored offices is not statistically related to external illuminances. Therefore, it is important to analyse occupants' behaviour patterns in order to reduce excessive lighting energy consumption.
Cited by 0 works.