공용접지방식의 철도시스템에서 지락고장시험에 의한 고장전류 분류 및 전위 분포 특성
유향복, 임진옥, 이형수 et al. · 한국철도학회 학술발표대회논문집 · 2012
Power supply system of electric railway is compose with distribution line, electric rolling stock, rail, track circuit of signal and communication, protection facilities and so on. All device of electric railway system is connected by buried earth wire. Power supply distribution systems are consisted of catenary condutcor, an overhead protective wire and a buried earth wire. Phase to ground faults are possible one of the maximum number of faults in the power distribution system of the electric railway. During a ground fault the maximum fault current and neutral to ground voltage will appear at the rail nearest to the fault. point. In this paper phase to ground faults were staged at the specified steel pole along the rail and measured the ground fault current distribution in the ground fault current, and measured potential nearest to the fault point.
Cited by 0 works.