기초 매스콘크리트의 수화열 저감을 위한 초지연제 응결시간차 공법의 현장 적용

황인성, 배정렬, 윤석명 et al. · 2003

This paper presents the results of field experiment to apply the difference of setting time method using super retarding agent for reducing hydration heat of mass concrete of foundation. According to the results, as the properties of fresh concrete, base concrete satisfies aimed slump and air content, and there is no difference of slump and air content with mixture of super retarding agent. The mixing ratio of super retarding agent is determined for setting time to be retarded by 12 hours in comparison with base concrete, but because the temperature of the air and concrete is low, the difference of setting time is retarded to 24 hours. In mass concrete of foundation to which the difference of setting time method is applied, crack by hydration heat is not seen because the lower concrete of super retarding agent generates heat after generation of hydration heat of the upper concrete.

Cited by 0 works.