습식 다회선 초음파유량계의 특성평가 연구
이동근, 조용, 고재명 et al. · 유체기계 연구개발 발표회 논문집 · 2013
An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, 90° double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.
Cited by 0 works.