스윙형 역지 밸브의 열림 특성에 관한 실험적 연구

송석윤, 김양석, 박성근 et al. · 유체기계 연구개발 발표회 논문집 · 2003

The experimental apparatus is designed and installed to measure the disc positions with flow velocity, Vopen and Vmin for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as Vopen, and Vmin is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, Vmin is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is fully opened or the oscillation level of disc is reduced below 1°. The results show that the Vmin velocities for 3 inch and 6 inch swing check valves are about 15.6% and 4.8% higher than the Vopen velocities, respectively. Although the experiments were done with the stable uniform flow, additional experiments will be performed to determine the effects of the upstream disturbances.

Cited by 0 works.

Authors