극저온 환경에서 운용되는 배관의 구조 거동에 관한 연구

김유경, 최신범, 최재붕 et al. · 대한설비공학회 학술발표대회논문집 · 2009

As the LNG(Liquefied Natural Gas) has been recognized as sustainable energy resources, many researches to evaluate structural safety of equipments related on LNG plant were performed. Expecially, the cryogenic effect on structural integrity of cold box which is on of major components in LNG plant should be considered. The aim of this study is to describe structural behavior by considering cryogenic environment. To do this, the pipe used in ASU is analyzed by CFD(Computational Fluid Dynamics) and structural analyses. The result shows that elbow region is the most frailty by stress concentration due to the cryogenic environment. Thus, these effects should be considered when main devices such as heat exchanger, valves, pipes and etc in cold box are designed. This results will be useful to assess structural integrity of LNG plant.

Cited by 1 works.

Authors