해수제빙장치의 팽창밸브 개도에 따른 성능 특성

주우진, 변종영, 정태영 et al. · 한국동력기계공학회 학술대회 논문집 · 2009

This paper investigates optimum operating conditions to develop automatic system with high energy efficiency of a seawater ice machine which has rotating drum installed an evaporator inside it. The coefficient of performance(COP) was used as an index to evaluate energy efficiency of the machine and it was calculated by two different manners. The opening angle(OA) of electronic expansion valve(EEV)/controlvariable,wasadjustedwithin 50-100% range to estimate the energy efficiency of the machine. At first, we checked COP and superheat according to the variation of OA of the EEV and rpm of the drum. Then we analyzed that how the variation of OA and rpm of the drum have influence on the COP and superheat. Finally, we confirmed that optimum OA of EEV was 85~90% range and the rpm variation of the drum did not have influence on the COP and superheat.