배출가스 분석을 통한 연소식 에어히터용 저온전용 시험에 관한 연구

박승욱, 나병철, Jin Yong Kim et al. · 한국자동차공학회 춘 추계 학술대회 논문집 · 2006

The efficiency of common rail diesel engine is higher and higher, the loss of heat is lower and lower. It means it is difficult to use waste heat of engine for air conditioning. For that reason, engine independent heater for cabin room was required and fuel air heater was developed. Domestic requirenemt of Fuel pre heater is higher, t localization of the heater is required. Test method for fuel pre heater have to be developed because operation condition is severe and climate of domestic region is mild compared with other northern country. This research carried out analysis of exhaust gas of heater prototype and development of low temperature heater start tester. Low temperature start test result through test equipment was clearly visible.

Cited by 7 works.