가정용 냉장고에서 핀과 열선의 접촉여부에 따른 제상거동 해석
배진효, 이재헌 · 대한설비공학회 강연회 및 기타간행물 · 1993
This paper describes defrosting behavior in evaporator of a domestic refrigerator according to the contact condition between fin and heater. When the constant heat generation is provided through heating coil inside the heater, the defrosting behavior of the frost layer in conjuction with air flow by natural convection has been studied numerically. For numerical simulation, one of the fin assembly mounted periodically around evaporator tube has been selected. The result indicates that when the average temperature of frost layer was increased from -26℃ to 0℃, the average temperature of air gap was -5℃ in case of contact situation between fin and heater but 10℃ in case of noncontact situation. It took 3 minutes for average temperature of frost to reach 10℃ from -26℃ in case of contact situation between fin and heater but 5.2 minutes in case of noncontact situation.
Cited by 0 works.