О расчете потерь давления для газовой скважины, продукция которой содержит воду

Николаев Олег Валерьевич, Моисейкин Пётр Алексеевич, Стоноженко Иван Васильевич et al. · Вести газовой науки · 2015

Presence of liquid in gas wells products makes to use ratios of two-phase pipe hydrodynamics at calculations of pressure losses in stalks. Thus methods of well operation regimes calculation include cyclic procedures and require special software. The article suggests simplifi ed model for calculation of pressure drops in stably working wells, when there is liquid in the products of these wells. The model has been developed basing on the results of Gazprom VNIIGAZ experimental research implemented in 2005–2013. In accordance with the suggested model the l imits for ranges of physical parameters are determined. Within these limits the pressure drops could be calculated under a one-phase-fl ow pattern without essential loss of accuracy. A new ratio for minimal steady gas well debit is derived, which takes into consideration consumption content of liquid in a fl ow.