Thermal output is a big source of errors on measuring the thermal deformation of specimen when a strain gage is used. Although several methods have been developed and used to solve this problem, in the range of measuring temperature is limited. In this work, we introduce digital image correlation (DIC) technique to measure a full-field the thermal deformation of a aluminum plate. We compared the deformation results of DIC and strain gage to judge the capability of the DIC. Additionally, we measured the thermal deformation of a ring structure using DIC and the result was quite matched with theoretical solutions.