자연재생 촉매방식 매연여과장치의 실차시험에 관한 연구

신동길, 정용일 · 한국자동차공학회 춘 추계 학술대회 논문집 · 2004

Three retrofitted fleets are examined to understand possibility of application of a passive type DPF and the factors that are considered to improve its performance. Smoke test was achieved and back pressure and temperature was analysed every week, in order to check the operating condition and failure of the DPF systems. With the averaged pressure of the foregoing part of DPF, its operating condition can be monitored effectively and pressure level in that the DPF work normal operation was understood. In the present study, process of analysis, instrumentation and data logging on retrofitted fleets was improved. And the factors e.g. season temperature and engine condition that can affect the DPF operating were founded. The result of this study is expected to be useful reference to passive type DPF test.

Cited by 8 works.