동적열부하계산을 통한 공동주택 창호 단열사양에 따른 냉난방부하 절감효과 분석

윤성환, 송수빈, 김영탁 et al. · Journal of KIAEBS · 2008

This study is conducted to find out how the heating and cooling loads change by thermal performance by the dynamic heat load simulation program. The study results are as followings. (1) It is revealed that SC is changeable if a window is Low-E coated and by the colors of windows. U-value of window is highly related to the thickness and the kind of window rather than the colors of window. (2) The thermal insulation property of double window whose U-value is distributed 1-2W/㎡K is twice of the thermal insulation property of single window. The mean U-value of PVC window is about 1.0W/㎡K beneficial compared to the mean U-value of aluminum window, which is concluded that it is highly advantageous to take in consideration of the thermal insulation property. (3) As SC increases by 0.1, it shows that annual heating and cooling loads decrease by approximately 5%. And as U-value of window increases by 0.5W/㎡K, annual cooling and heating loads increase by approximately 15%. (4) The simulation results show that annual cooling and heating load is different by 134% to the utmost, as it is appeared to be minimums of 213 MJ/㎡ㆍyr in case of U-value0.6-SC0.6 and maximum of 499MJ/㎡ㆍyr in case of U-value3.0-SC0.4.