자동차용 에어컨 성능실험과 엑서지 해석
오상한, 윤종갑, 원성필 · 대한설비공학회 학술발표대회논문집 · 1999
Experiments have been performed, using pure refrigerant R134a and a zeotropic refrigerant mixture R290/R600a(60%/40%) and their results have been analyzed by the first and second laws (exergy method) of thermodynamics. From experimental results, variations of compressor speed and air temperature make the large effect on the performance of the system but the variation of air flow rate hardly affects the performance. The sum of exergy losses in compressor and evaporator is about 60% of total exergy loss, using refrigerant R134a, so it is necessary to improve the performance of compressor and evaporator. And subcooling and superheating hardly affect the performance of the system and their exergy losses are very small. When the experimental results, using refrigerant mixture of R290/R600a(60%/40%), have been analyzed, the exergy losses in heat exchange processes are decreased but the exergy loss in throttling process is increased. The performance of the system has been improved more 20~30% than that of R134a and exergy losses have been also reduced.
Cited by 0 works.