중온 응축부 온도 범위에서 편조윅 및 슬랩윅을 갖는 히트파이프의 성능 비교 연구

정원복, 부준홍, 곽희열 et al. · 대한기계학회 춘추학술대회 · 2001

A special working condition of elevated condenser temperature may arise in such case as a solar collector for a medium temperature range. For this case, a heat pipe must be designed properly such that it may transfer a certain amount of heat to the abnormally hot condenser from the evaporator of which the relative temperature potential is not so high as in common applications. In addition, the working fluid properties become unfavorable due to an elevated temperature of the whole heat pipe. Among many wick structure candidates for this application, a slab wick and a woven-wire wick were selected based on the promising performance data published previously. The thermal performance of heat pipes made of these two wick types were or investigated for comparison. In addition, the performance of a thermosyphon in the same working condition was also investigated for a reference in the comparison study. The typical range of condenser wall temperature was set between 80 and 120 ℃. The heat pipes were made of 9.53 ㎜ dia. copper tubes. The experimental data of these heat pipes were analysed and discussed in terms of thermal resistance against thermal load and coolant temperature.