제3종 하이브리드 환기시스템을 적용한 공동주택의 환기성능 예측
황지현, 오창용, 김무현 · 설비공학논문집 · 2006
A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, 120 m³/h. As the results, residents feel comfortable thermally for 60 m³/h. In the case of 120 m³/h, however, residents feel uncomfortable both thermally and in air currents. In this study the energy saving for space heating is also an important factor. In the case of whole region with 180 m³/h, residents feel comfortable at each region of the model apartment. It is shown that this hybrid ventilation system is possible method for the apartment house.