산업용 전기집진기 내 유동 균일성에 대한 입구 디퓨저 확장각의 영향

권현구, 박석환, 조형희 et al. · 대한설비공학회 학술발표대회논문집 · 2006

Industrial electrostatic precipitators require a highly uniform velocity distribution in the collecting chamber. Increasing divergence angle of a diffuser makes a non-uniformity flow distribution characteristics on the diffuser exit. This paper provides CFD results of optimum positions and opening rates of perforated plates which were installed in the electrostatic precipitator. The considered divergence angels were 60 degree and 90 degree. In 90 degree diffuser, a blanking method was used.