장대 교통터널의 피난연락갱 설치 간격에 관한 실험적 연구

유용호, 윤찬훈, 윤성욱 et al. · 터널과 지하공간 · 2005

The objective of this study was to analyze the smoke movement for the case of fire and to determine the interval between emergency exits in long tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was constructed by acrylic tubes and tests were carried out systematically. From the strong relationship between CO propagation time and distance through the tunnel. it was found that the optimal escaping time was 6 minutes in case of 20㎿ fire. But. regarding passengers' psychological state under fire, another one minute of delay time should be considered. Therefore, the total escaping time should be estimated by 5 minutes. The interval between the emergency exits for vehicle passengers was calculated by 250 m with respect to the 5 minute of escaping time.